Luminex · Control and signal

LumiNode 1

ModelLU 01 00069

With its unique USB to Ethernet feature, LumiNode 1 functions as an Ethernet dongle enabling you to have a fully functional ethernet port when connected to your laptop/PC.

PriceOn request

Prices on request. We confirm the configuration, availability and lead time for each project; quotations exclude installation, programming, freight and VAT unless agreed otherwise.

01SpecificationManufacturer's data · 10 groups · 43 values

What this product is, in numbers.

The manufacturer's published values. We confirm the configuration and the values that matter for your project before an order.

01Connectivity4
DMX/RDM connectivity
1x Neutrik 5 pin XLR (female) shielded & gold plated
Ethernet connectivity
1x shielded Neutrik Ethercon connector 1x USB to Ethernet (dongle function)
Contact closure
No
Power connectivity
USB Ethernet (PoE 802.3af class 0)
02DMX features4
DMX protocols
DMX512 (1986 & 1990) DMX512-A ANSI E1.11 RDM ANSI E1.20-2010
DMX port direction
Input or output (configurable)
DMX port isolation
Optical and galvanic isolation per port
DMX timing
Framerate: 10-40fps Break: 176-352µs
03Network features5
Ethernet protocols
Art-Net™ (1-4) sACN ANSI E1.31 RTTrPL (BlackTraX) KiNET v1, v2
Ethernet port speed
10/100/1000 Mbps
Port sensing
Auto-negociation MDI / MDIX
Split management interface
Yes
Groups (VLAN) support
Yes
04Key features11
Process engines
2
Merging engine
HTP LTP Backup Switch X-Fade Custom
Softpatch
Yes
Master/Limit
Proportional Limit
Trigger system
Yes
ReRoute
Yes
Profile manager
Yes
Snapshot
Yes
DMX Redundancy
Yes
Monitoring software
LumiNet Monitor
Configuration
Built in Web server Documented Web API
05Status2
Display and jog
No
Status LEDs
Ethernet Port: link/activity LED and Group RGB LED DMX Port: DMX/RDM LED
06Power3
Power input
USB PoE IEEE 802.3af (Class 0)
Power consumption
Maximum 6 W
Power redundancy
Yes
Show the full specificationHide the rest of the specification4 more groups · 14 values
07Environmental3
Operating temperature
0 tot +60°C
Storage temperature
-10 tot +70°C
Humidity (non condensing)
5 to 95% RH
08Physical6
Enclosure
Robust metal enclosure
Mounting
NA
Dimensions (W x D x H)
131,5 × 73,3 × 44 mm
Weight
0,42 kg
Packaging
200 × 140 × 60 mm
Box content
LumiNode Quick Start Guide USB-A to USB-B cable
09Approvals4
Electromagnetic emissions and immunity
EN55032 class A EN55035 EN61000-3-2 EN61000-3-3 EN61000-4-2 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 FCC Part 15 CFR 47 class A ICES-003 Issue 6
Safety
IEC 62368-1 EN 62368-1 UL 62368-1 CAN/CSA-C22.2 No. 62368-1 CE
Certificates
cSGSus Mark CE CB certificate
Green
RoHS REACH
10Product codes1
Product codes
LU 01 00069 (LumiNode 1 with PoE input)
02DescriptionManufacturer's description

What it is.

USB Ethernet dongle

With its unique USB to Ethernet feature, LumiNode 1 functions as an Ethernet dongle enabling you to have a fully functional ethernet port when connected to your laptop/PC. LumiNode 1 works with any network-based lighting control software without the need to install additional drivers.

1 port node

LumiNode 1 can also be used as a one-port PoE powered, stand-alone node to serve either one bi-directional, fully isolated DMX port or 2 network process engines to route protocols around, test, parameterize and take over light kits even with RDM, without consoles or other complex systems.

All relevant industry standard protocols such as Art-Net, sACN, KiNET, RTTRpl (Blacktrax) are supported and can be processed and converted by the 2 onboard process engines supporting HTP, LTP, Crossfade, Backup, Switch and Custom merging modes with soft patch functionality.

Industry protocols

All relevant industry-standard protocols such as Art-Net, sACN, KiNET, RTTrPL (Blacktrax) are supported.

The LumiNode family is fully DMX/RDM compatible. LumiNet Monitor and other third party RDM software or lighting consoles (supporting ArtNet RDM) can make use of the full RDM functionality.

Intuitive UI

The built-in web UI delivers a great user experience. Process engines can be easily configured in a very intuitive workflow. Just decide what you like to do with your lighting data by choosing the mode of the process engine.

Depending on the chosen merging/routing policy of the engine, the UI presents all possible input configurations. From here you just connect your input streams and your output connections. Everything can be easily stored and recalled into profiles for later usage.

Advanced networking

Use the full capacity of the Gigabit connectivity by sending different data in a different Group (VLAN). Setup a separate interface for IT monitoring without interfering with critical lighting data. The known Group (VLAN) technology from GigaCore switches is also available in the LumiNode product family.

This allows you to freely assign a different Group (VLAN) to the different network connectors and to the node’s interfaces. ISL (Inter Switch Link) and custom trunks are available to transfer different VLANs on one ethernet connection.

Integration with web API

LumiNode features a fully documented web API, making the unit ideal for integration and automation in installation projects.

All configuration or manipulation (like recalling profiles, configuring engines, triggering play,…) can be done via web API (REST/JSON). Offering the maximum flexibility to integrate with any other hardware or software to control your infrastructure.

Today

LuminNode product family is built for today's connectivity needs, like converting network protocols to DMX/RDM outputs meanwhile merging and routing different sources together.

Today's converters limitations are the amount of DMX connectors on the unit and what you like to do with these. LumiNode features a vast amount of merging and routing process engines beyond the amount of DMX ports, allowing you to decide what you like to achieve with the incoming data rather than what you are allowed to do with a DMX port only.

Tomorrow

Tomorrow's lighting rigs are and will be ever more Ethernet connected and LumiNode will make sure that all different controls can talk with different fixtures. For this reason Luminex introduced the concept of process engines. Process engines let you define what you like or need to do with incoming data streams from different controls, protocols or even internal sources. And allows you to choose what output needs to be generated out of it. This can be a variety of different lighting control protocols and not necessarily a DMX/RDM output.

The output of a process engine can even serve multiple DMX/RDM ports and network protocols at once.

Future proof

The LumiNode product family offers more process engines than physical DMX connectors. Meaning your investment scales with the ever growing need for more network connected data and still being able to do what you need today.

Specifications LumiNode 1

*Note: Luminex LCE operates a policy of continuous development. Luminex LCE reserves the right to make changes and improvements to any of the products described in this document above without prior notice. Specifications are subject to change without notice.

03Documents1 file · 291 KB

Documents and files.

Datasheets, manuals, drawings and certificates as the manufacturer publishes them.

05Talk to us
LumiNode 1Luminex · EQ-4763

Need this priced for your project?

  1. Quantity and site
  2. Configuration and interfaces
  3. Quotation