IP-02 · Two-floor distribution
Typical two-floor distribution with one calculated 10 Gb/s optical link.
Signal flow
All 9 connections · 10 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · SA3 HDMI sources
To · EA3 encoders - fixed TX
Direction: source → destination · 3 HDMI with audio
From · EA3 encoders - fixed TX
To · WA1 access switch A 7 endpoint ports PSE at least 263 W
Direction: source → destination · 3 x 1G + PoE+
From · WA1 access switch A 7 endpoint ports PSE at least 263 W
To · DA4 decoders - fixed RX
Direction: source → destination · 4 x 1G + PoE+
From · DA4 decoders - fixed RX
To · VA4 displays
Direction: source → destination · 4 HDMI with audio
From · SB3 HDMI sources
To · EB3 encoders - fixed TX
Direction: source → destination · 3 HDMI with audio
From · EB3 encoders - fixed TX
To · WB1 access switch B 7 endpoint ports PSE at least 263 W
Direction: source → destination · 3 x 1G + PoE+
From · WB1 access switch B 7 endpoint ports PSE at least 263 W
To · DB4 decoders - fixed RX
Direction: source → destination · 4 x 1G + PoE+
From · DB4 decoders - fixed RX
To · VB4 displays
Direction: source → destination · 4 HDMI with audio
From · WA1 access switch A 7 endpoint ports PSE at least 263 W
To · WB1 access switch B 7 endpoint ports PSE at least 263 W
Bidirectional · 1 duplex fibre / 2 SFP+ 10G each direction; budget 3.75G each
SA · 3 HDMI sources
Connections: L01. Repeated device IDs refer to the same equipment.
EA · 3 encoders - fixed TX
Connections: L01, L02. Repeated device IDs refer to the same equipment.
WA · 1 access switch A 7 endpoint ports PSE at least 263 W
Connections: L02, L03, L13. Repeated device IDs refer to the same equipment.
DA · 4 decoders - fixed RX
Connections: L03, L04. Repeated device IDs refer to the same equipment.
VA · 4 displays
Connections: L04. Repeated device IDs refer to the same equipment.
SB · 3 HDMI sources
Connections: L07. Repeated device IDs refer to the same equipment.
EB · 3 encoders - fixed TX
Connections: L07, L08. Repeated device IDs refer to the same equipment.
WB · 1 access switch B 7 endpoint ports PSE at least 263 W
Connections: L08, L09, L13. Repeated device IDs refer to the same equipment.
DB · 4 decoders - fixed RX
Connections: L09, L10. Repeated device IDs refer to the same equipment.
VB · 4 displays
Connections: L10. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 9 connections
- Typical two-floor distribution with one calculated 10 Gb/s optical link.
- Each floor has three encoders and four decoders, joined by access switches and a fibre link; two clients use one controller.
- SA
- 3 HDMI sources
- EA
- 3 encoders - fixed TX
- WA
- 1 access switch A 7 endpoint ports PSE at least 263 W
- DA
- 4 decoders - fixed RX
- VA
- 4 displays
- SB
- 3 HDMI sources
- EB
- 3 encoders - fixed TX
- WB
- 1 access switch B 7 endpoint ports PSE at least 263 W
- DB
- 4 decoders - fixed RX
- VB
- 4 displays
- SA → EA3 HDMI with audio
- EA → WA3 x 1G + PoE+
- WA → DA4 x 1G + PoE+
- DA → VA4 HDMI with audio
- SB → EB3 HDMI with audio
- EB → WB3 x 1G + PoE+
- WB → DB4 x 1G + PoE+
- DB → VB4 HDMI with audio
- WA ↔ WB1 duplex fibre / 2 SFP+ 10G each direction; budget 3.75G each
BASE: one L2 AV VLAN; management VLAN separate Dashed control shares the physical Ethernet links One selected primary video feed per decoder USB, multiview, independent AoIP and streaming excluded
Control & status
All 12 connections · 11 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · DA4 decoders - fixed RX
To · WA1 access switch A 7 endpoint ports PSE at least 263 W
Direction: source → destination · IGMP membership + status
From · UA1 wired operator client Local power
To · WA1 access switch A 7 endpoint ports PSE at least 263 W
Direction: source → destination · 1G wired access
From · DB4 decoders - fixed RX
To · WB1 access switch B 7 endpoint ports PSE at least 263 W
Direction: source → destination · IGMP membership + status
From · UB1 wired operator client Local power
To · WB1 access switch B 7 endpoint ports PSE at least 263 W
Direction: source → destination · 1G wired access
From · CTRL1 route controller Local power; programmed UI + drivers
To · WA1 access switch A 7 endpoint ports PSE at least 263 W
Direction: source → destination · commands via switch
From · WA1 access switch A 7 endpoint ports PSE at least 263 W
To · CTRL1 route controller Local power; programmed UI + drivers
Direction: source → destination · endpoint status via switch
From · GW1 client IT gateway interface AV + management VLAN trunk
To · WA1 access switch A 7 endpoint ports PSE at least 263 W
Direction: source → destination · allowed unicast services
From · ITClient IT services and administration No media routing to corporate network
To · GW1 client IT gateway interface AV + management VLAN trunk
Bidirectional · firewall policy
From · WA1 access switch A 7 endpoint ports PSE at least 263 W
To · DA4 decoders - fixed RX
Direction: source → destination · route commands
From · EA3 encoders - fixed TX
To · WA1 access switch A 7 endpoint ports PSE at least 263 W
Direction: source → destination · source status
From · WB1 access switch B 7 endpoint ports PSE at least 263 W
To · DB4 decoders - fixed RX
Direction: source → destination · route commands
From · EB3 encoders - fixed TX
To · WB1 access switch B 7 endpoint ports PSE at least 263 W
Direction: source → destination · source status
EA · 3 encoders - fixed TX
Connections: L19. Repeated device IDs refer to the same equipment.
WA · 1 access switch A 7 endpoint ports PSE at least 263 W
Connections: L05, L06, L14, L15, L16, L18, L19. Repeated device IDs refer to the same equipment.
DA · 4 decoders - fixed RX
Connections: L05, L18. Repeated device IDs refer to the same equipment.
UA · 1 wired operator client Local power
Connections: L06. Repeated device IDs refer to the same equipment.
EB · 3 encoders - fixed TX
Connections: L21. Repeated device IDs refer to the same equipment.
WB · 1 access switch B 7 endpoint ports PSE at least 263 W
Connections: L11, L12, L20, L21. Repeated device IDs refer to the same equipment.
DB · 4 decoders - fixed RX
Connections: L11, L20. Repeated device IDs refer to the same equipment.
UB · 1 wired operator client Local power
Connections: L12. Repeated device IDs refer to the same equipment.
CTRL · 1 route controller Local power; programmed UI + drivers
Connections: L14, L15. Repeated device IDs refer to the same equipment.
GW · 1 client IT gateway interface AV + management VLAN trunk
Connections: L16, L17. Repeated device IDs refer to the same equipment.
IT · Client IT services and administration No media routing to corporate network
Connections: L17. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 12 connections
- Typical two-floor distribution with one calculated 10 Gb/s optical link.
- Each floor has three encoders and four decoders, joined by access switches and a fibre link; two clients use one controller.
- EA
- 3 encoders - fixed TX
- WA
- 1 access switch A 7 endpoint ports PSE at least 263 W
- DA
- 4 decoders - fixed RX
- UA
- 1 wired operator client Local power
- EB
- 3 encoders - fixed TX
- WB
- 1 access switch B 7 endpoint ports PSE at least 263 W
- DB
- 4 decoders - fixed RX
- UB
- 1 wired operator client Local power
- CTRL
- 1 route controller Local power; programmed UI + drivers
- GW
- 1 client IT gateway interface AV + management VLAN trunk
- IT
- Client IT services and administration No media routing to corporate network
- DA → WAIGMP membership + status
- UA → WA1G wired access
- DB → WBIGMP membership + status
- UB → WB1G wired access
- CTRL → WAcommands via switch
- WA → CTRLendpoint status via switch
- GW → WAallowed unicast services
- IT ↔ GWfirewall policy
- WA → DAroute commands
- EA → WAsource status
- WB → DBroute commands
- EB → WBsource status
BASE: one L2 AV VLAN; management VLAN separate Dashed control shares the physical Ethernet links One selected primary video feed per decoder USB, multiview, independent AoIP and streaming excluded
Typical architecture · not a project drawing