IP-03 · Three-building distribution
Typical three-building distribution; R01 spare links are a separate option.
Signal flow
All 15 connections · 16 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · SA4 HDMI sources
To · EA4 encoders - fixed TX
Direction: source → destination · 4 HDMI with audio
From · EA4 encoders - fixed TX
To · WA1 access switch A 10 endpoint ports PSE at least 375 W
Direction: source → destination · 4 x 1G + PoE+
From · WA1 access switch A 10 endpoint ports PSE at least 375 W
To · DA6 decoders - fixed RX
Direction: source → destination · 6 x 1G + PoE+
From · DA6 decoders - fixed RX
To · VA6 displays
Direction: source → destination · 6 HDMI with audio
From · SB4 HDMI sources
To · EB4 encoders - fixed TX
Direction: source → destination · 4 HDMI with audio
From · EB4 encoders - fixed TX
To · WB1 access switch B 10 endpoint ports PSE at least 375 W
Direction: source → destination · 4 x 1G + PoE+
From · WB1 access switch B 10 endpoint ports PSE at least 375 W
To · DB6 decoders - fixed RX
Direction: source → destination · 6 x 1G + PoE+
From · DB6 decoders - fixed RX
To · VB6 displays
Direction: source → destination · 6 HDMI with audio
From · SC4 HDMI sources
To · EC4 encoders - fixed TX
Direction: source → destination · 4 HDMI with audio
From · EC4 encoders - fixed TX
To · WC1 access switch C 10 endpoint ports PSE at least 375 W
Direction: source → destination · 4 x 1G + PoE+
From · WC1 access switch C 10 endpoint ports PSE at least 375 W
To · DC6 decoders - fixed RX
Direction: source → destination · 6 x 1G + PoE+
From · DC6 decoders - fixed RX
To · VC6 displays
Direction: source → destination · 6 HDMI with audio
From · WA1 access switch A 10 endpoint ports PSE at least 375 W
To · CORE1 shared core 3 base fibre links / 6 SFP+ Single core; no core HA
Bidirectional · 10G fibre TX budget 5G / RX 7.5G
From · WB1 access switch B 10 endpoint ports PSE at least 375 W
To · CORE1 shared core 3 base fibre links / 6 SFP+ Single core; no core HA
Bidirectional · 10G fibre TX budget 5G / RX 7.5G
From · WC1 access switch C 10 endpoint ports PSE at least 375 W
To · CORE1 shared core 3 base fibre links / 6 SFP+ Single core; no core HA
Bidirectional · 10G fibre TX budget 5G / RX 7.5G
SA · 4 HDMI sources
Connections: L01. Repeated device IDs refer to the same equipment.
EA · 4 encoders - fixed TX
Connections: L01, L02. Repeated device IDs refer to the same equipment.
WA · 1 access switch A 10 endpoint ports PSE at least 375 W
Connections: L02, L03, L19. Repeated device IDs refer to the same equipment.
DA · 6 decoders - fixed RX
Connections: L03, L04. Repeated device IDs refer to the same equipment.
VA · 6 displays
Connections: L04. Repeated device IDs refer to the same equipment.
SB · 4 HDMI sources
Connections: L07. Repeated device IDs refer to the same equipment.
EB · 4 encoders - fixed TX
Connections: L07, L08. Repeated device IDs refer to the same equipment.
WB · 1 access switch B 10 endpoint ports PSE at least 375 W
Connections: L08, L09, L20. Repeated device IDs refer to the same equipment.
DB · 6 decoders - fixed RX
Connections: L09, L10. Repeated device IDs refer to the same equipment.
VB · 6 displays
Connections: L10. Repeated device IDs refer to the same equipment.
SC · 4 HDMI sources
Connections: L13. Repeated device IDs refer to the same equipment.
EC · 4 encoders - fixed TX
Connections: L13, L14. Repeated device IDs refer to the same equipment.
WC · 1 access switch C 10 endpoint ports PSE at least 375 W
Connections: L14, L15, L21. Repeated device IDs refer to the same equipment.
DC · 6 decoders - fixed RX
Connections: L15, L16. Repeated device IDs refer to the same equipment.
VC · 6 displays
Connections: L16. Repeated device IDs refer to the same equipment.
CORE · 1 shared core 3 base fibre links / 6 SFP+ Single core; no core HA
Connections: L19, L20, L21. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 15 connections
- Typical three-building distribution; R01 spare links are a separate option.
- Three groups of four encoders and six decoders connect through access switches to one core, with a central controller and one client per building.
- SA
- 4 HDMI sources
- EA
- 4 encoders - fixed TX
- WA
- 1 access switch A 10 endpoint ports PSE at least 375 W
- DA
- 6 decoders - fixed RX
- VA
- 6 displays
- SB
- 4 HDMI sources
- EB
- 4 encoders - fixed TX
- WB
- 1 access switch B 10 endpoint ports PSE at least 375 W
- DB
- 6 decoders - fixed RX
- VB
- 6 displays
- SC
- 4 HDMI sources
- EC
- 4 encoders - fixed TX
- WC
- 1 access switch C 10 endpoint ports PSE at least 375 W
- DC
- 6 decoders - fixed RX
- VC
- 6 displays
- CORE
- 1 shared core 3 base fibre links / 6 SFP+ Single core; no core HA
- SA → EA4 HDMI with audio
- EA → WA4 x 1G + PoE+
- WA → DA6 x 1G + PoE+
- DA → VA6 HDMI with audio
- SB → EB4 HDMI with audio
- EB → WB4 x 1G + PoE+
- WB → DB6 x 1G + PoE+
- DB → VB6 HDMI with audio
- SC → EC4 HDMI with audio
- EC → WC4 x 1G + PoE+
- WC → DC6 x 1G + PoE+
- DC → VC6 HDMI with audio
- WA ↔ CORE10G fibre TX budget 5G / RX 7.5G
- WB ↔ CORE10G fibre TX budget 5G / RX 7.5G
- WC ↔ CORE10G fibre TX budget 5G / RX 7.5G
BASE: one L2 AV VLAN; management VLAN separate Dashed control shares the physical Ethernet links One selected primary video feed per decoder USB, multiview, independent AoIP and streaming excluded
Control & status
All 17 connections · 17 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · DA6 decoders - fixed RX
To · WA1 access switch A 10 endpoint ports PSE at least 375 W
Direction: source → destination · IGMP membership + status
From · UA1 wired operator client Local power
To · WA1 access switch A 10 endpoint ports PSE at least 375 W
Direction: source → destination · 1G wired access
From · DB6 decoders - fixed RX
To · WB1 access switch B 10 endpoint ports PSE at least 375 W
Direction: source → destination · IGMP membership + status
From · UB1 wired operator client Local power
To · WB1 access switch B 10 endpoint ports PSE at least 375 W
Direction: source → destination · 1G wired access
From · DC6 decoders - fixed RX
To · WC1 access switch C 10 endpoint ports PSE at least 375 W
Direction: source → destination · IGMP membership + status
From · UC1 wired operator client Local power
To · WC1 access switch C 10 endpoint ports PSE at least 375 W
Direction: source → destination · 1G wired access
From · OPTOPTION R01 ONLY +3 separate fibre paths / +6 SFP+ Second path per access to SAME core RSTP: one path blocked; no 20G claim
To · CORE1 shared core 3 base fibre links / 6 SFP+ Single core; no core HA
Direction: source → destination · uses second uplink on A, B and C
From · CTRL1 route controller Local power; programmed UI + drivers
To · CORE1 shared core 3 base fibre links / 6 SFP+ Single core; no core HA
Direction: source → destination · commands via switch
From · CORE1 shared core 3 base fibre links / 6 SFP+ Single core; no core HA
To · CTRL1 route controller Local power; programmed UI + drivers
Direction: source → destination · endpoint status via switch
From · GW1 client IT gateway interface AV + management VLAN trunk
To · CORE1 shared core 3 base fibre links / 6 SFP+ Single core; no core HA
Direction: source → destination · allowed unicast services
From · ITClient IT services and administration No media routing to corporate network
To · GW1 client IT gateway interface AV + management VLAN trunk
Bidirectional · firewall policy
From · WA1 access switch A 10 endpoint ports PSE at least 375 W
To · DA6 decoders - fixed RX
Direction: source → destination · route commands
From · EA4 encoders - fixed TX
To · WA1 access switch A 10 endpoint ports PSE at least 375 W
Direction: source → destination · source status
From · WB1 access switch B 10 endpoint ports PSE at least 375 W
To · DB6 decoders - fixed RX
Direction: source → destination · route commands
From · EB4 encoders - fixed TX
To · WB1 access switch B 10 endpoint ports PSE at least 375 W
Direction: source → destination · source status
From · WC1 access switch C 10 endpoint ports PSE at least 375 W
To · DC6 decoders - fixed RX
Direction: source → destination · route commands
From · EC4 encoders - fixed TX
To · WC1 access switch C 10 endpoint ports PSE at least 375 W
Direction: source → destination · source status
EA · 4 encoders - fixed TX
Connections: L28. Repeated device IDs refer to the same equipment.
WA · 1 access switch A 10 endpoint ports PSE at least 375 W
Connections: L05, L06, L27, L28. Repeated device IDs refer to the same equipment.
DA · 6 decoders - fixed RX
Connections: L05, L27. Repeated device IDs refer to the same equipment.
UA · 1 wired operator client Local power
Connections: L06. Repeated device IDs refer to the same equipment.
EB · 4 encoders - fixed TX
Connections: L30. Repeated device IDs refer to the same equipment.
WB · 1 access switch B 10 endpoint ports PSE at least 375 W
Connections: L11, L12, L29, L30. Repeated device IDs refer to the same equipment.
DB · 6 decoders - fixed RX
Connections: L11, L29. Repeated device IDs refer to the same equipment.
UB · 1 wired operator client Local power
Connections: L12. Repeated device IDs refer to the same equipment.
EC · 4 encoders - fixed TX
Connections: L32. Repeated device IDs refer to the same equipment.
WC · 1 access switch C 10 endpoint ports PSE at least 375 W
Connections: L17, L18, L31, L32. Repeated device IDs refer to the same equipment.
DC · 6 decoders - fixed RX
Connections: L17, L31. Repeated device IDs refer to the same equipment.
UC · 1 wired operator client Local power
Connections: L18. Repeated device IDs refer to the same equipment.
CORE · 1 shared core 3 base fibre links / 6 SFP+ Single core; no core HA
Connections: L22, L23, L24, L25. Repeated device IDs refer to the same equipment.
OPT · OPTION R01 ONLY +3 separate fibre paths / +6 SFP+ Second path per access to SAME core RSTP: one path blocked; no 20G claim
Connections: L22. Repeated device IDs refer to the same equipment.
CTRL · 1 route controller Local power; programmed UI + drivers
Connections: L23, L24. Repeated device IDs refer to the same equipment.
GW · 1 client IT gateway interface AV + management VLAN trunk
Connections: L25, L26. Repeated device IDs refer to the same equipment.
IT · Client IT services and administration No media routing to corporate network
Connections: L26. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 17 connections
- Typical three-building distribution; R01 spare links are a separate option.
- Three groups of four encoders and six decoders connect through access switches to one core, with a central controller and one client per building.
- EA
- 4 encoders - fixed TX
- WA
- 1 access switch A 10 endpoint ports PSE at least 375 W
- DA
- 6 decoders - fixed RX
- UA
- 1 wired operator client Local power
- EB
- 4 encoders - fixed TX
- WB
- 1 access switch B 10 endpoint ports PSE at least 375 W
- DB
- 6 decoders - fixed RX
- UB
- 1 wired operator client Local power
- EC
- 4 encoders - fixed TX
- WC
- 1 access switch C 10 endpoint ports PSE at least 375 W
- DC
- 6 decoders - fixed RX
- UC
- 1 wired operator client Local power
- CORE
- 1 shared core 3 base fibre links / 6 SFP+ Single core; no core HA
- OPT
- OPTION R01 ONLY +3 separate fibre paths / +6 SFP+ Second path per access to SAME core RSTP: one path blocked; no 20G claim
- CTRL
- 1 route controller Local power; programmed UI + drivers
- GW
- 1 client IT gateway interface AV + management VLAN trunk
- IT
- Client IT services and administration No media routing to corporate network
- DA → WAIGMP membership + status
- UA → WA1G wired access
- DB → WBIGMP membership + status
- UB → WB1G wired access
- DC → WCIGMP membership + status
- UC → WC1G wired access
- OPT → COREuses second uplink on A, B and C
- CTRL → COREcommands via switch
- CORE → CTRLendpoint status via switch
- GW → COREallowed unicast services
- IT ↔ GWfirewall policy
- WA → DAroute commands
- EA → WAsource status
- WB → DBroute commands
- EB → WBsource status
- WC → DCroute commands
- EC → WCsource status
BASE: one L2 AV VLAN; management VLAN separate Dashed control shares the physical Ethernet links One selected primary video feed per decoder USB, multiview, independent AoIP and streaming excluded
Typical architecture · not a project drawing