EV-01 · Small permanent stage
Twelve stage sources feed the house and monitor mixes. Basic lighting has isolated DMX branches. Presentation LED is optional.
AUDIO
All 7 connections · 8 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · EV01_MIC8 x wired microphones
To · EV01_PATCH1 x passive multicore 12 sends / 4 returns
Direction: source → destination · balanced mic
From · EV01_DI2 x DI channels
To · EV01_PATCH1 x passive multicore 12 sends / 4 returns
Direction: source → destination · balanced mic or line
From · EV01_RF2 x complete wireless channels
To · EV01_PATCH1 x passive multicore 12 sends / 4 returns
Direction: source → destination · receiver audio
From · EV01_PATCH1 x passive multicore 12 sends / 4 returns
To · EV01_MIX1 x FOH mixer 16 mono inputs / 8 line outputs
Direction: source → destination · 12 analogue inputs
From · EV01_MIX1 x FOH mixer 16 mono inputs / 8 line outputs
To · EV01_SUB2 x powered subwoofers LPF set locally
Direction: source → destination · L/R via returns 1-2
From · EV01_SUB2 x powered subwoofers LPF set locally
To · EV01_TOP2 x powered main speakers HPF set locally
Direction: source → destination · full-range THRU, L and R
From · EV01_MIX1 x FOH mixer 16 mono inputs / 8 line outputs
To · EV01_MON2 x powered stage monitors 2 independent mono mixes
Direction: source → destination · aux 1-2 via returns 3-4
EV01_MIC · 8 x wired microphones
Connections: L01. Repeated device IDs refer to the same equipment.
EV01_PATCH · 1 x passive multicore 12 sends / 4 returns
Connections: L01, L02, L03, L04. Repeated device IDs refer to the same equipment.
EV01_DI · 2 x DI channels
Connections: L02. Repeated device IDs refer to the same equipment.
EV01_RF · 2 x complete wireless channels
Connections: L03. Repeated device IDs refer to the same equipment.
EV01_MIX · 1 x FOH mixer 16 mono inputs / 8 line outputs
Connections: L04, L05, L07. Repeated device IDs refer to the same equipment.
EV01_SUB · 2 x powered subwoofers LPF set locally
Connections: L05, L06. Repeated device IDs refer to the same equipment.
EV01_TOP · 2 x powered main speakers HPF set locally
Connections: L06. Repeated device IDs refer to the same equipment.
EV01_MON · 2 x powered stage monitors 2 independent mono mixes
Connections: L07. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 7 connections
- Twelve stage sources feed the house and monitor mixes. Basic lighting has isolated DMX branches. Presentation LED is optional.
- EV-01 reference signal diagram showing stage audio, a FOH mixer, powered loudspeakers, four lighting fixtures and an optional presentation path.
- EV01_MIC
- 8 x wired microphones
- EV01_PATCH
- 1 x passive multicore 12 sends / 4 returns
- EV01_DI
- 2 x DI channels
- EV01_RF
- 2 x complete wireless channels
- EV01_MIX
- 1 x FOH mixer 16 mono inputs / 8 line outputs
- EV01_SUB
- 2 x powered subwoofers LPF set locally
- EV01_TOP
- 2 x powered main speakers HPF set locally
- EV01_MON
- 2 x powered stage monitors 2 independent mono mixes
- EV01_MIC → EV01_PATCHbalanced mic
- EV01_DI → EV01_PATCHbalanced mic or line
- EV01_RF → EV01_PATCHreceiver audio
- EV01_PATCH → EV01_MIX12 analogue inputs
- EV01_MIX → EV01_SUBL/R via returns 1-2
- EV01_SUB → EV01_TOPfull-range THRU, L and R
- EV01_MIX → EV01_MONaux 1-2 via returns 3-4
LIGHTING
All 5 connections · 5 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · OPVenue technician
To · EV01_LC1 x lighting console
Direction: source → destination · scene / level / blackout
From · EV01_LC1 x lighting console
To · EV01_SPLIT1 x isolated splitter 4 outputs, same universe
Direction: source → destination · DMX U1
From · EV01_SPLIT1 x isolated splitter 4 outputs, same universe
To · EV01_LIGHT4 x profile fixtures optics and mounting included
Direction: source → destination · 4 separate DMX branches
From · EV01_LIGHT4 x profile fixtures optics and mounting included
To · EV01_TERM4 x 120 ohm terminators
Connection · one at each branch end
From · EV01_LIGHT4 x profile fixtures optics and mounting included
To · OPVenue technician
Direction: source → destination · operator visual check not automatic status
OP · Venue technician
Connections: L08, L12. Repeated device IDs refer to the same equipment.
EV01_LC · 1 x lighting console
Connections: L08, L09. Repeated device IDs refer to the same equipment.
EV01_SPLIT · 1 x isolated splitter 4 outputs, same universe
Connections: L09, L10. Repeated device IDs refer to the same equipment.
EV01_LIGHT · 4 x profile fixtures optics and mounting included
Connections: L10, L11, L12. Repeated device IDs refer to the same equipment.
EV01_TERM · 4 x 120 ohm terminators
Connections: L11. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 5 connections
- Twelve stage sources feed the house and monitor mixes. Basic lighting has isolated DMX branches. Presentation LED is optional.
- EV-01 reference signal diagram showing stage audio, a FOH mixer, powered loudspeakers, four lighting fixtures and an optional presentation path.
- OP
- Venue technician
- EV01_LC
- 1 x lighting console
- EV01_SPLIT
- 1 x isolated splitter 4 outputs, same universe
- EV01_LIGHT
- 4 x profile fixtures optics and mounting included
- EV01_TERM
- 4 x 120 ohm terminators
- OP → EV01_LCscene / level / blackout
- EV01_LC → EV01_SPLITDMX U1
- EV01_SPLIT → EV01_LIGHT4 separate DMX branches
- EV01_LIGHT — EV01_TERMone at each branch end
- EV01_LIGHT → OPoperator visual check not automatic status
PRESENTATION OPTION
All 6 connections · 7 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · EV01_PC1 x content laptop customer supplied
To · EV01_PRES1 x presentation switcher 2 inputs / 1 output + audio extraction
Direction: source → destination · HDMI
From · EV01_PRES1 x presentation switcher 2 inputs / 1 output + audio extraction
To · EV01_LEDPROC1 x LED processor
Direction: source → destination · HDMI
From · EV01_LEDPROC1 x LED processor
To · EV01_LED1 x indoor LED assembly size and pixels by design
Direction: source → destination · matched LED data
From · EV01_PRES1 x presentation switcher 2 inputs / 1 output + audio extraction
To · EV01_STEREO1 x stereo isolation interface
Direction: source → destination · stereo analogue
From · EV01_STEREO1 x stereo isolation interface
To · MIXREFSame FOH mixer local inputs 13-14; total 14/16
Direction: source → destination · balanced L/R
From · EV01_VIDINFRA1 x display infrastructure allowance
To · EV01_LED1 x indoor LED assembly size and pixels by design
Direction: source → destination · power / support / cabling
EV01_PC · 1 x content laptop customer supplied
Connections: L13. Repeated device IDs refer to the same equipment.
EV01_PRES · 1 x presentation switcher 2 inputs / 1 output + audio extraction
Connections: L13, L14, L16. Repeated device IDs refer to the same equipment.
EV01_LEDPROC · 1 x LED processor
Connections: L14, L15. Repeated device IDs refer to the same equipment.
EV01_LED · 1 x indoor LED assembly size and pixels by design
Connections: L15, L18. Repeated device IDs refer to the same equipment.
EV01_STEREO · 1 x stereo isolation interface
Connections: L16, L17. Repeated device IDs refer to the same equipment.
MIXREF · Same FOH mixer local inputs 13-14; total 14/16
Connections: L17. Repeated device IDs refer to the same equipment.
EV01_VIDINFRA · 1 x display infrastructure allowance
Connections: L18. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 6 connections
- Twelve stage sources feed the house and monitor mixes. Basic lighting has isolated DMX branches. Presentation LED is optional.
- EV-01 reference signal diagram showing stage audio, a FOH mixer, powered loudspeakers, four lighting fixtures and an optional presentation path.
- EV01_PC
- 1 x content laptop customer supplied
- EV01_PRES
- 1 x presentation switcher 2 inputs / 1 output + audio extraction
- EV01_LEDPROC
- 1 x LED processor
- EV01_LED
- 1 x indoor LED assembly size and pixels by design
- EV01_STEREO
- 1 x stereo isolation interface
- MIXREF
- Same FOH mixer local inputs 13-14; total 14/16
- EV01_VIDINFRA
- 1 x display infrastructure allowance
- EV01_PC → EV01_PRESHDMI
- EV01_PRES → EV01_LEDPROCHDMI
- EV01_LEDPROC → EV01_LEDmatched LED data
- EV01_PRES → EV01_STEREOstereo analogue
- EV01_STEREO → MIXREFbalanced L/R
- EV01_VIDINFRA → EV01_LEDpower / support / cabling
INFRASTRUCTURE
All 3 connections · 4 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · EV01_INFRA1 x installation allowance power, supports, cables, supplies
To · POWERREFSame powered PA, monitors and light
Direction: source → destination · separately sized AC circuits
From · EV01_INFRA1 x installation allowance power, supports, cables, supplies
To · NOTEProject load / route / mounting schedules required
Connection · See source and destination requirements.
From · EV01_SPARES1 x service spares schedule
To · NOTEProject load / route / mounting schedules required
Connection · See source and destination requirements.
EV01_INFRA · 1 x installation allowance power, supports, cables, supplies
Connections: L19, L20. Repeated device IDs refer to the same equipment.
POWERREF · Same powered PA, monitors and light
Connections: L19. Repeated device IDs refer to the same equipment.
NOTE · Project load / route / mounting schedules required
Connections: L20, L21. Repeated device IDs refer to the same equipment.
EV01_SPARES · 1 x service spares schedule
Connections: L21. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 3 connections
- Twelve stage sources feed the house and monitor mixes. Basic lighting has isolated DMX branches. Presentation LED is optional.
- EV-01 reference signal diagram showing stage audio, a FOH mixer, powered loudspeakers, four lighting fixtures and an optional presentation path.
- EV01_INFRA
- 1 x installation allowance power, supports, cables, supplies
- POWERREF
- Same powered PA, monitors and light
- NOTE
- Project load / route / mounting schedules required
- EV01_SPARES
- 1 x service spares schedule
- EV01_INFRA → POWERREFseparately sized AC circuits
- EV01_INFRA — NOTE
- EV01_SPARES — NOTE
Typical architecture · not a project drawing