EV-03 · Outdoor stage with guest production
Stage and FOH exchange media over identified fibre services, with separate guest interfaces and a manually patched spare route.
AUDIO
All 13 connections · 14 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · EV03_MIC16 x wired microphones
To · SOURCESHouse stage sources installation-suitable equipment
Direction: source → destination · See source and destination requirements.
From · EV03_DI4 x DI channels
To · SOURCESHouse stage sources installation-suitable equipment
Direction: source → destination · See source and destination requirements.
From · EV03_RF4 x complete wireless channels
To · SOURCESHouse stage sources installation-suitable equipment
Direction: source → destination · See source and destination requirements.
From · SOURCESHouse stage sources installation-suitable equipment
To · EV03_IO1 x network stagebox 32 inputs / 16 outputs
Direction: source → destination · 24 mic / line
From · GAGuest stereo programme
To · EV03_ISOL1 x stereo line isolation
Direction: source → destination · balanced XLR L/R
From · EV03_ISOL1 x stereo line isolation
To · EV03_IO1 x network stagebox 32 inputs / 16 outputs
Direction: source → destination · inputs 25-26; phantom off
From · EV03_IO1 x network stagebox 32 inputs / 16 outputs
To · EV03_MIX1 x FOH console 32 input channels + local I/O
Bidirectional · network audio via transport panel 26 inputs / 6 returns
From · EV03_IO1 x network stagebox 32 inputs / 16 outputs
To · EV03_PA1 x outdoor PA assembly DSP and amplification included
Direction: source → destination · out 1-2: L/R
From · EV03_IO1 x network stagebox 32 inputs / 16 outputs
To · EV03_MON4 x powered stage monitors planning allowance
Direction: source → destination · out 3-6: aux 1-4
From · PCREFSame content laptop
To · EV03_USB1 x stereo USB audio interface
Direction: source → destination · USB
From · EV03_USB1 x stereo USB audio interface
To · EV03_MIX1 x FOH console 32 input channels + local I/O
Direction: source → destination · 2 local balanced inputs
From · EV03_MIX1 x FOH console 32 input channels + local I/O
To · EV03_LEVEL1 x stereo level interface isolation / attenuation
Direction: source → destination · programme L/R: 2 local outs
From · EV03_LEVEL1 x stereo level interface isolation / attenuation
To · AVREFSame HD switcher analogue input 1, line mode
Direction: source → destination · unbalanced stereo; checked peak
EV03_MIC · 16 x wired microphones
Connections: L01. Repeated device IDs refer to the same equipment.
SOURCES · House stage sources installation-suitable equipment
Connections: L01, L02, L03, L04. Repeated device IDs refer to the same equipment.
EV03_DI · 4 x DI channels
Connections: L02. Repeated device IDs refer to the same equipment.
EV03_RF · 4 x complete wireless channels
Connections: L03. Repeated device IDs refer to the same equipment.
EV03_IO · 1 x network stagebox 32 inputs / 16 outputs
Connections: L04, L06, L07, L08, L09. Repeated device IDs refer to the same equipment.
GA · Guest stereo programme
Connections: L05. Repeated device IDs refer to the same equipment.
EV03_ISOL · 1 x stereo line isolation
Connections: L05, L06. Repeated device IDs refer to the same equipment.
EV03_MIX · 1 x FOH console 32 input channels + local I/O
Connections: L07, L11, L12. Repeated device IDs refer to the same equipment.
EV03_PA · 1 x outdoor PA assembly DSP and amplification included
Connections: L08. Repeated device IDs refer to the same equipment.
EV03_MON · 4 x powered stage monitors planning allowance
Connections: L09. Repeated device IDs refer to the same equipment.
PCREF · Same content laptop
Connections: L10. Repeated device IDs refer to the same equipment.
EV03_USB · 1 x stereo USB audio interface
Connections: L10, L11. Repeated device IDs refer to the same equipment.
EV03_LEVEL · 1 x stereo level interface isolation / attenuation
Connections: L12, L13. Repeated device IDs refer to the same equipment.
AVREF · Same HD switcher analogue input 1, line mode
Connections: L13. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 13 connections
- Stage and FOH exchange media over identified fibre services, with separate guest interfaces and a manually patched spare route.
- EV-03 reference diagram showing outdoor venue sound, guest connections, four optical SDI paths, network audio and lighting, and environmental operating boundaries.
- EV03_MIC
- 16 x wired microphones
- SOURCES
- House stage sources installation-suitable equipment
- EV03_DI
- 4 x DI channels
- EV03_RF
- 4 x complete wireless channels
- EV03_IO
- 1 x network stagebox 32 inputs / 16 outputs
- GA
- Guest stereo programme
- EV03_ISOL
- 1 x stereo line isolation
- EV03_MIX
- 1 x FOH console 32 input channels + local I/O
- EV03_PA
- 1 x outdoor PA assembly DSP and amplification included
- EV03_MON
- 4 x powered stage monitors planning allowance
- PCREF
- Same content laptop
- EV03_USB
- 1 x stereo USB audio interface
- EV03_LEVEL
- 1 x stereo level interface isolation / attenuation
- AVREF
- Same HD switcher analogue input 1, line mode
- EV03_MIC → SOURCES
- EV03_DI → SOURCES
- EV03_RF → SOURCES
- SOURCES → EV03_IO24 mic / line
- GA → EV03_ISOLbalanced XLR L/R
- EV03_ISOL → EV03_IOinputs 25-26; phantom off
- EV03_IO ↔ EV03_MIXnetwork audio via transport panel 26 inputs / 6 returns
- EV03_IO → EV03_PAout 1-2: L/R
- EV03_IO → EV03_MONout 3-6: aux 1-4
- PCREF → EV03_USBUSB
- EV03_USB → EV03_MIX2 local balanced inputs
- EV03_MIX → EV03_LEVELprogramme L/R: 2 local outs
- EV03_LEVEL → AVREFunbalanced stereo; checked peak
VIDEO
All 13 connections · 14 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · EV03_CAM2 x SDI cameras selected for installation conditions
To · OPTCAMOptical pairs 1-2 2 Tx at stage / 2 Rx at FOH
Direction: source → destination · SDI
From · OPTCAMOptical pairs 1-2 2 Tx at stage / 2 Rx at FOH
To · EV03_VIDEO1 x HD SDI switcher in controlled FOH
Direction: source → destination · SDI inputs 1-2
From · GVGuest HD SDI input
To · OPTGOptical pair 3 stage Tx / FOH Rx
Direction: source → destination · SDI
From · OPTGOptical pair 3 stage Tx / FOH Rx
To · EV03_VIDEO1 x HD SDI switcher in controlled FOH
Direction: source → destination · SDI input 4
From · EV03_PC1 x content laptop customer supplied
To · EV03_CONV1 x HDMI to SDI converter
Direction: source → destination · HDMI
From · EV03_CONV1 x HDMI to SDI converter
To · EV03_VIDEO1 x HD SDI switcher in controlled FOH
Direction: source → destination · SDI input 3; audio off
From · EV03_VIDEO1 x HD SDI switcher in controlled FOH
To · OPTROptical pair 4 FOH Tx / stage Rx
Direction: source → destination · SDI out 1: programme
From · OPTROptical pair 4 FOH Tx / stage Rx
To · EV03_LEDPROC1 x LED processor in controlled stage enclosure
Direction: source → destination · SDI
From · EV03_LEDPROC1 x LED processor in controlled stage enclosure
To · EV03_LED1 x outdoor LED assembly
Direction: source → destination · matched LED data
From · EV03_VIDEO1 x HD SDI switcher in controlled FOH
To · EV03_MV1 x SDI source monitor
Direction: source → destination · out 2: SDI multiview
From · EV03_VIDEO1 x HD SDI switcher in controlled FOH
To · EV03_SSD1 x recording drive validation required
Direction: source → destination · USB programme recording
From · EV03_VIDEO1 x HD SDI switcher in controlled FOH
To · EV03_WAN1 x customer WAN / streaming service
Direction: source → destination · stream via FOH LAN
From · EV03_WAN1 x customer WAN / streaming service
To · CHECKAuthorised test viewer
Direction: source → destination · external playback check
EV03_CAM · 2 x SDI cameras selected for installation conditions
Connections: L14. Repeated device IDs refer to the same equipment.
OPTCAM · Optical pairs 1-2 2 Tx at stage / 2 Rx at FOH
Connections: L14, L15. Repeated device IDs refer to the same equipment.
EV03_VIDEO · 1 x HD SDI switcher in controlled FOH
Connections: L15, L17, L19, L20, L23, L24, L25. Repeated device IDs refer to the same equipment.
GV · Guest HD SDI input
Connections: L16. Repeated device IDs refer to the same equipment.
OPTG · Optical pair 3 stage Tx / FOH Rx
Connections: L16, L17. Repeated device IDs refer to the same equipment.
EV03_PC · 1 x content laptop customer supplied
Connections: L18. Repeated device IDs refer to the same equipment.
EV03_CONV · 1 x HDMI to SDI converter
Connections: L18, L19. Repeated device IDs refer to the same equipment.
OPTR · Optical pair 4 FOH Tx / stage Rx
Connections: L20, L21. Repeated device IDs refer to the same equipment.
EV03_LEDPROC · 1 x LED processor in controlled stage enclosure
Connections: L21, L22. Repeated device IDs refer to the same equipment.
EV03_LED · 1 x outdoor LED assembly
Connections: L22. Repeated device IDs refer to the same equipment.
EV03_MV · 1 x SDI source monitor
Connections: L23. Repeated device IDs refer to the same equipment.
EV03_SSD · 1 x recording drive validation required
Connections: L24. Repeated device IDs refer to the same equipment.
EV03_WAN · 1 x customer WAN / streaming service
Connections: L25, L26. Repeated device IDs refer to the same equipment.
CHECK · Authorised test viewer
Connections: L26. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 13 connections
- Stage and FOH exchange media over identified fibre services, with separate guest interfaces and a manually patched spare route.
- EV-03 reference diagram showing outdoor venue sound, guest connections, four optical SDI paths, network audio and lighting, and environmental operating boundaries.
- EV03_CAM
- 2 x SDI cameras selected for installation conditions
- OPTCAM
- Optical pairs 1-2 2 Tx at stage / 2 Rx at FOH
- EV03_VIDEO
- 1 x HD SDI switcher in controlled FOH
- GV
- Guest HD SDI input
- OPTG
- Optical pair 3 stage Tx / FOH Rx
- EV03_PC
- 1 x content laptop customer supplied
- EV03_CONV
- 1 x HDMI to SDI converter
- OPTR
- Optical pair 4 FOH Tx / stage Rx
- EV03_LEDPROC
- 1 x LED processor in controlled stage enclosure
- EV03_LED
- 1 x outdoor LED assembly
- EV03_MV
- 1 x SDI source monitor
- EV03_SSD
- 1 x recording drive validation required
- EV03_WAN
- 1 x customer WAN / streaming service
- CHECK
- Authorised test viewer
- EV03_CAM → OPTCAMSDI
- OPTCAM → EV03_VIDEOSDI inputs 1-2
- GV → OPTGSDI
- OPTG → EV03_VIDEOSDI input 4
- EV03_PC → EV03_CONVHDMI
- EV03_CONV → EV03_VIDEOSDI input 3; audio off
- EV03_VIDEO → OPTRSDI out 1: programme
- OPTR → EV03_LEDPROCSDI
- EV03_LEDPROC → EV03_LEDmatched LED data
- EV03_VIDEO → EV03_MVout 2: SDI multiview
- EV03_VIDEO → EV03_SSDUSB programme recording
- EV03_VIDEO → EV03_WANstream via FOH LAN
- EV03_WAN → CHECKexternal playback check
TRANSPORT
All 5 connections · 6 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · EV03_PATCH2 x passive patch points stage and FOH
To · EV03_FIBRE2 x OS2 trunks, 12 fibres each active + manual spare route
Connection · See source and destination requirements.
From · EV03_NET2 x managed switches one stage / one FOH
To · EV03_SFP2 x duplex SFP modules 1 matched Ethernet pair
Bidirectional · one SFP per switch
From · EV03_SFP2 x duplex SFP modules 1 matched Ethernet pair
To · EV03_FIBRE2 x OS2 trunks, 12 fibres each active + manual spare route
Bidirectional · active fibres 1-2 network audio / control / sACN
From · EV03_SDIOPT4 x SDI Tx/Rx pairs 8 endpoints total; same pairs 1-4 above
To · EV03_FIBRE2 x OS2 trunks, 12 fibres each active + manual spare route
Bidirectional · active fibres 3-6 3 toward FOH, 1 toward stage
From · EV03_FIBRE2 x OS2 trunks, 12 fibres each active + manual spare route
To · RECOVEROperator recovery procedure spare fibres 1-6 carry same services
Direction: source → destination · manual repatch after fault no automatic failover
EV03_PATCH · 2 x passive patch points stage and FOH
Connections: L27. Repeated device IDs refer to the same equipment.
EV03_FIBRE · 2 x OS2 trunks, 12 fibres each active + manual spare route
Connections: L27, L29, L30, L31. Repeated device IDs refer to the same equipment.
EV03_NET · 2 x managed switches one stage / one FOH
Connections: L28. Repeated device IDs refer to the same equipment.
EV03_SFP · 2 x duplex SFP modules 1 matched Ethernet pair
Connections: L28, L29. Repeated device IDs refer to the same equipment.
EV03_SDIOPT · 4 x SDI Tx/Rx pairs 8 endpoints total; same pairs 1-4 above
Connections: L30. Repeated device IDs refer to the same equipment.
RECOVER · Operator recovery procedure spare fibres 1-6 carry same services
Connections: L31. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 5 connections
- Stage and FOH exchange media over identified fibre services, with separate guest interfaces and a manually patched spare route.
- EV-03 reference diagram showing outdoor venue sound, guest connections, four optical SDI paths, network audio and lighting, and environmental operating boundaries.
- EV03_PATCH
- 2 x passive patch points stage and FOH
- EV03_FIBRE
- 2 x OS2 trunks, 12 fibres each active + manual spare route
- EV03_NET
- 2 x managed switches one stage / one FOH
- EV03_SFP
- 2 x duplex SFP modules 1 matched Ethernet pair
- EV03_SDIOPT
- 4 x SDI Tx/Rx pairs 8 endpoints total; same pairs 1-4 above
- RECOVER
- Operator recovery procedure spare fibres 1-6 carry same services
- EV03_PATCH — EV03_FIBRE
- EV03_NET ↔ EV03_SFPone SFP per switch
- EV03_SFP ↔ EV03_FIBREactive fibres 1-2 network audio / control / sACN
- EV03_SDIOPT ↔ EV03_FIBREactive fibres 3-6 3 toward FOH, 1 toward stage
- EV03_FIBRE → RECOVERmanual repatch after fault no automatic failover
CONTROL
All 13 connections · 12 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · EV03_OPS1 x control workstation local monitor included
To · NETREFSame stage and FOH switches segmented network via fibres 1-2
Bidirectional · management commands / actual status
From · EV03_PTZ1 x camera controller
To · NETREFSame stage and FOH switches segmented network via fibres 1-2
Bidirectional · IP commands / status
From · NETREFSame stage and FOH switches segmented network via fibres 1-2
To · CAMREFSame two cameras
Bidirectional · camera presets / state
From · NETREFSame stage and FOH switches segmented network via fibres 1-2
To · VIDREFSame video switcher / LED processor
Bidirectional · record / stream / device state
From · EV03_LC1 x house lighting console
To · NETREFSame stage and FOH switches segmented network via fibres 1-2
Direction: source → destination · sACN, two universes
From · GCTLGuest lighting network input exclusive authorised sender
To · NETREFSame stage and FOH switches segmented network via fibres 1-2
Direction: source → destination · lighting VLAN only
From · NETREFSame stage and FOH switches segmented network via fibres 1-2
To · EV03_NODE1 x isolated two-port DMX node
Direction: source → destination · sACN
From · EV03_NODE1 x isolated two-port DMX node
To · EV03_LIGHT8 x front-light fixtures installation-suitable
Direction: source → destination · U1: daisy chain
From · EV03_NODE1 x isolated two-port DMX node
To · EV03_WASH4 x wash fixtures installation-suitable
Direction: source → destination · U2: daisy chain
From · EV03_LIGHT8 x front-light fixtures installation-suitable
To · EV03_TERM2 x 120 ohm terminators one per universe branch
Connection · end of U1 branch
From · EV03_WASH4 x wash fixtures installation-suitable
To · EV03_TERM2 x 120 ohm terminators one per universe branch
Connection · end of U2 branch
From · EV03_LIGHT8 x front-light fixtures installation-suitable
To · TECHVenue operator
Direction: source → destination · visual observation
From · EV03_WASH4 x wash fixtures installation-suitable
To · TECHVenue operator
Direction: source → destination · visual observation
EV03_OPS · 1 x control workstation local monitor included
Connections: L32. Repeated device IDs refer to the same equipment.
NETREF · Same stage and FOH switches segmented network via fibres 1-2
Connections: L32, L33, L34, L35, L36, L37, L38. Repeated device IDs refer to the same equipment.
EV03_PTZ · 1 x camera controller
Connections: L33. Repeated device IDs refer to the same equipment.
CAMREF · Same two cameras
Connections: L34. Repeated device IDs refer to the same equipment.
VIDREF · Same video switcher / LED processor
Connections: L35. Repeated device IDs refer to the same equipment.
EV03_LC · 1 x house lighting console
Connections: L36. Repeated device IDs refer to the same equipment.
GCTL · Guest lighting network input exclusive authorised sender
Connections: L37. Repeated device IDs refer to the same equipment.
EV03_NODE · 1 x isolated two-port DMX node
Connections: L38, L39, L40. Repeated device IDs refer to the same equipment.
EV03_LIGHT · 8 x front-light fixtures installation-suitable
Connections: L39, L41, L43. Repeated device IDs refer to the same equipment.
EV03_WASH · 4 x wash fixtures installation-suitable
Connections: L40, L42, L44. Repeated device IDs refer to the same equipment.
EV03_TERM · 2 x 120 ohm terminators one per universe branch
Connections: L41, L42. Repeated device IDs refer to the same equipment.
TECH · Venue operator
Connections: L43, L44. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 13 connections
- Stage and FOH exchange media over identified fibre services, with separate guest interfaces and a manually patched spare route.
- EV-03 reference diagram showing outdoor venue sound, guest connections, four optical SDI paths, network audio and lighting, and environmental operating boundaries.
- EV03_OPS
- 1 x control workstation local monitor included
- NETREF
- Same stage and FOH switches segmented network via fibres 1-2
- EV03_PTZ
- 1 x camera controller
- CAMREF
- Same two cameras
- VIDREF
- Same video switcher / LED processor
- EV03_LC
- 1 x house lighting console
- GCTL
- Guest lighting network input exclusive authorised sender
- EV03_NODE
- 1 x isolated two-port DMX node
- EV03_LIGHT
- 8 x front-light fixtures installation-suitable
- EV03_WASH
- 4 x wash fixtures installation-suitable
- EV03_TERM
- 2 x 120 ohm terminators one per universe branch
- TECH
- Venue operator
- EV03_OPS ↔ NETREFmanagement commands / actual status
- EV03_PTZ ↔ NETREFIP commands / status
- NETREF ↔ CAMREFcamera presets / state
- NETREF ↔ VIDREFrecord / stream / device state
- EV03_LC → NETREFsACN, two universes
- GCTL → NETREFlighting VLAN only
- NETREF → EV03_NODEsACN
- EV03_NODE → EV03_LIGHTU1: daisy chain
- EV03_NODE → EV03_WASHU2: daisy chain
- EV03_LIGHT — EV03_TERMend of U1 branch
- EV03_WASH — EV03_TERMend of U2 branch
- EV03_LIGHT → TECHvisual observation
- EV03_WASH → TECHvisual observation
SITE AND OPERATION
All 8 connections · 12 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · EV03_ENV1 x environmental monitoring system
To · OPSREFSame control workstation / operator
Direction: source → destination · alarms via management LAN
From · EV03_ENC1 x controlled-environment allowance stage / FOH enclosures, HVAC, cable entries
To · LIMITEvery device / connector / support checked against site conditions
Connection · See source and destination requirements.
From · EV03_INFRA1 x installation allowance electrical distribution, supports and routes
To · POWERREFSame PA, LED and lighting systems
Direction: source → destination · separately sized AC circuits
From · EV03_INFRA1 x installation allowance electrical distribution, supports and routes
To · LIMITEvery device / connector / support checked against site conditions
Connection · See source and destination requirements.
From · EV03_UPS1 x control-rack UPS not full-stage backup
To · UPSREFSame control and recording rack selected loads only
Direction: source → destination · protected control power
From · EV03_SPARES1 x service spares schedule
To · LIMITEvery device / connector / support checked against site conditions
Connection · See source and destination requirements.
From · EV03_GUEST1 x external guest-production boundary customer team and equipment
To · CONTRACTApproved guest interface sheet
Connection · See source and destination requirements.
From · EV03_ISO1 x optional ISO recording workflow resize and test storage
To · CONTRACTApproved guest interface sheet
Connection · See source and destination requirements.
EV03_ENV · 1 x environmental monitoring system
Connections: L45. Repeated device IDs refer to the same equipment.
OPSREF · Same control workstation / operator
Connections: L45. Repeated device IDs refer to the same equipment.
EV03_ENC · 1 x controlled-environment allowance stage / FOH enclosures, HVAC, cable entries
Connections: L46. Repeated device IDs refer to the same equipment.
LIMIT · Every device / connector / support checked against site conditions
Connections: L46, L48, L50. Repeated device IDs refer to the same equipment.
EV03_INFRA · 1 x installation allowance electrical distribution, supports and routes
Connections: L47, L48. Repeated device IDs refer to the same equipment.
POWERREF · Same PA, LED and lighting systems
Connections: L47. Repeated device IDs refer to the same equipment.
EV03_UPS · 1 x control-rack UPS not full-stage backup
Connections: L49. Repeated device IDs refer to the same equipment.
UPSREF · Same control and recording rack selected loads only
Connections: L49. Repeated device IDs refer to the same equipment.
EV03_SPARES · 1 x service spares schedule
Connections: L50. Repeated device IDs refer to the same equipment.
EV03_GUEST · 1 x external guest-production boundary customer team and equipment
Connections: L51. Repeated device IDs refer to the same equipment.
CONTRACT · Approved guest interface sheet
Connections: L51, L52. Repeated device IDs refer to the same equipment.
EV03_ISO · 1 x optional ISO recording workflow resize and test storage
Connections: L52. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 8 connections
- Stage and FOH exchange media over identified fibre services, with separate guest interfaces and a manually patched spare route.
- EV-03 reference diagram showing outdoor venue sound, guest connections, four optical SDI paths, network audio and lighting, and environmental operating boundaries.
- EV03_ENV
- 1 x environmental monitoring system
- OPSREF
- Same control workstation / operator
- EV03_ENC
- 1 x controlled-environment allowance stage / FOH enclosures, HVAC, cable entries
- LIMIT
- Every device / connector / support checked against site conditions
- EV03_INFRA
- 1 x installation allowance electrical distribution, supports and routes
- POWERREF
- Same PA, LED and lighting systems
- EV03_UPS
- 1 x control-rack UPS not full-stage backup
- UPSREF
- Same control and recording rack selected loads only
- EV03_SPARES
- 1 x service spares schedule
- EV03_GUEST
- 1 x external guest-production boundary customer team and equipment
- CONTRACT
- Approved guest interface sheet
- EV03_ISO
- 1 x optional ISO recording workflow resize and test storage
- EV03_ENV → OPSREFalarms via management LAN
- EV03_ENC — LIMIT
- EV03_INFRA → POWERREFseparately sized AC circuits
- EV03_INFRA — LIMIT
- EV03_UPS → UPSREFprotected control power
- EV03_SPARES — LIMIT
- EV03_GUEST — CONTRACT
- EV03_ISO — CONTRACT
Typical architecture · not a project drawing