A shared operational view CR-01

Reference design; project validation required.

Discuss this option →

Choose a view, then a route, connection or device. Lines retain their original direction. Repeated device IDs refer to the same equipment across views.

CR-01 · Shared operational overview

Keep four agreed sources visible while two operators work locally.

Signal flow

Signal flow. Devices, connections and conditions follow the drawing.Open SVG ↗
CR-01 · Signal flowReference design. Four information PCs feed four capture channels and four LCD outputs. Two local operator positions use two of those same PCs. Layout commands and status use a separate management network. No KVM or processor redundancy. Reference design, not a site plan. Rack, 2 PDU, wall mount and cable/PSU sets: separate BOQ lines. UPS does not duplicate the compositor. No switched KVM. Repeated device identifiers refer to the same equipment across views. Equipment illustrations are schematic; labels define quantities.{"sourceHash":"d57319bb4cab516c8e190b53fba01a7c97740a3bcae2f27a3c450541b936a905","view":"signal","nodes":["SRC","PROC","WALL","DESK"],"edges":["L01","L02","L03","L04"]}PIXEL COMMAND SOLUTIONS / CR-01 / SIGNAL FLOWSignal flowREFERENCE DESIGN · PROJECT VALIDATION REQUIREDSRC → PROC: 4 HDMI feeds; 1080p60 assumed4 HDMI feedsPROC → WALL: 4 separate panel feeds4 separate panel feedsSRC → DESK: 2 additional local display outputs2 additional localdisplay outputsDESK → SRC: local keyboard and mouse USBlocal keyboard andmouse USB4 x source PCs S1 and S2 are the local operator PCsSRC4 x source PCs1 x wall compositor 4 capture channels / 4 panel outputsPROC1 x wall compositor4 x LCD panels 2 by 2; FHD per panel assumedWALL4 x LCD panels2 x local operator sets monitor + keyboard + mouse; no extra PCsDESK2 x local operatorsetsVideo / LED dataUSB / KVM
Devices, connections & design conditions 4 connections
  • Four HDMI sources feed four capture channels.
  • Four separate outputs drive the LCD panels.
  • Two local desks use two of those source PCs; layout control is separate.
SRC
4 x source PCs S1 and S2 are the local operator PCs
PROC
1 x wall compositor 4 capture channels / 4 panel outputs
WALL
4 x LCD panels 2 by 2; FHD per panel assumed
DESK
2 x local operator sets monitor + keyboard + mouse; no extra PCs
  1. SRC → PROC4 HDMI feeds; 1080p60 assumed
  2. PROC → WALL4 separate panel feeds
  3. SRC → DESK2 additional local display outputs
  4. DESK → SRClocal keyboard and mouse USB

Reference design, not a site plan. Rack, 2 PDU, wall mount and cable/PSU sets: separate BOQ lines. UPS does not duplicate the compositor. No switched KVM.

Control & status

Signal flow. Devices, connections and conditions follow the drawing.Open SVG ↗
CR-01 · Control & statusReference design. Four information PCs feed four capture channels and four LCD outputs. Two local operator positions use two of those same PCs. Layout commands and status use a separate management network. No KVM or processor redundancy. Reference design, not a site plan. Rack, 2 PDU, wall mount and cable/PSU sets: separate BOQ lines. UPS does not duplicate the compositor. No switched KVM. Repeated device identifiers refer to the same equipment across views. Equipment illustrations are schematic; labels define quantities.{"sourceHash":"d57319bb4cab516c8e190b53fba01a7c97740a3bcae2f27a3c450541b936a905","view":"control","nodes":["PROC","WALL","PANEL","NET","UPS"],"edges":["L05","L06","L07","L08"]}PIXEL COMMAND SOLUTIONS / CR-01 / CONTROL & STATUSControl & statusREFERENCE DESIGN · PROJECT VALIDATION REQUIREDPANEL ↔ NET: IP: commands / active stateIP: commands / activestateNET ↔ PROC: IP: presets / input loss / display statusIP: presets / inputloss / display statusNET ↔ WALL: IP: panel control and statusIP: panel control andstatusUPS → NET: power status; mains circuits omittedpower status1 x wall compositor 4 capture channels / 4 panel outputsPROC1 x wall compositor4 x LCD panels 2 by 2; FHD per panel assumedWALL4 x LCD panels1 x layout panel authorised scene userPANEL1 x layout panel1 x management switch 16 ports; 7 used + 1 serviceNET1 x management switch1 x UPS system source, desk, control and wall loads sized separatelyUPS1 x UPS systemControl / status
Devices, connections & design conditions 4 connections
  • Four HDMI sources feed four capture channels.
  • Four separate outputs drive the LCD panels.
  • Two local desks use two of those source PCs; layout control is separate.
PROC
1 x wall compositor 4 capture channels / 4 panel outputs
WALL
4 x LCD panels 2 by 2; FHD per panel assumed
PANEL
1 x layout panel authorised scene user
NET
1 x management switch 16 ports; 7 used + 1 service
UPS
1 x UPS system source, desk, control and wall loads sized separately
  1. PANEL ↔ NETIP: commands / active state
  2. NET ↔ PROCIP: presets / input loss / display status
  3. NET ↔ WALLIP: panel control and status
  4. UPS → NETpower status; mains circuits omitted

Reference design, not a site plan. Rack, 2 PDU, wall mount and cable/PSU sets: separate BOQ lines. UPS does not duplicate the compositor. No switched KVM.

Typical architecture · not a project drawing