MR-03 · Conference room with two camera views
Two captures feed the PC for manual camera selection. Two processed microphone mixes feed the call, while playback returns to four speakers and both echo references.
Signal flow
All 9 connections · 8 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · CAM2 SDI PTZ cameras Separate 12 V supply per camera
To · CAP2 SDI-to-USB captures One per camera; embedded audio off
Direction: source → destination · 2 separate 3G-SDI lines
From · CAP2 SDI-to-USB captures One per camera; embedded audio off
To · PC1 dedicated room PC Manual camera selection in call app
Direction: source → destination · 2 USB 3 video paths; test host topology
From · PC1 dedicated room PC Manual camera selection in call app
To · DIS2 displays 86-inch candidates; independent outputs
Direction: source → destination · 2 HDMI outputs; layout depends on app
From · PC1 dedicated room PC Manual camera selection in call app
To · REMRemote participants / service One selected camera in baseline
Bidirectional · IP call and application content sharing
From · MIC2 ceiling microphone arrays AEC and automatic coverage ON in each
To · DSP1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
Direction: source → destination · Dante: 2 processed automixes to RX1 / RX2
From · DSP1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
To · SPK4 powered network speakers Same mono playback bus
Direction: source → destination · TX1 multicast: 1 flow to 4 speakers
From · DSP1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
To · MIC2 ceiling microphone arrays AEC and automatic coverage ON in each
Direction: source → destination · TX2 multicast: 1 flow to both AEC references
From · DSP1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
To · PC1 dedicated room PC Manual camera selection in call app
Direction: source → destination · USB send: mixed local speech only
From · PC1 dedicated room PC Manual camera selection in call app
To · DSP1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
Direction: source → destination · USB playback: far end + content
CAM · 2 SDI PTZ cameras Separate 12 V supply per camera
Connections: L01. Repeated device IDs refer to the same equipment.
CAP · 2 SDI-to-USB captures One per camera; embedded audio off
Connections: L01, L02. Repeated device IDs refer to the same equipment.
PC · 1 dedicated room PC Manual camera selection in call app
Connections: L02, L03, L04, L08, L09. Repeated device IDs refer to the same equipment.
DIS · 2 displays 86-inch candidates; independent outputs
Connections: L03. Repeated device IDs refer to the same equipment.
REM · Remote participants / service One selected camera in baseline
Connections: L04. Repeated device IDs refer to the same equipment.
MIC · 2 ceiling microphone arrays AEC and automatic coverage ON in each
Connections: L05, L07. Repeated device IDs refer to the same equipment.
DSP · 1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
Connections: L05, L06, L07, L08, L09. Repeated device IDs refer to the same equipment.
SPK · 4 powered network speakers Same mono playback bus
Connections: L06. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 9 connections
- Two captures feed the PC for manual camera selection. Two processed microphone mixes feed the call, while playback returns to four speakers and both echo references.
- MR-03 reference diagram showing two cameras and displays, two microphone arrays, audio return, room controls and the managed network.
- CAM
- 2 SDI PTZ cameras Separate 12 V supply per camera
- CAP
- 2 SDI-to-USB captures One per camera; embedded audio off
- PC
- 1 dedicated room PC Manual camera selection in call app
- DIS
- 2 displays 86-inch candidates; independent outputs
- REM
- Remote participants / service One selected camera in baseline
- MIC
- 2 ceiling microphone arrays AEC and automatic coverage ON in each
- DSP
- 1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
- SPK
- 4 powered network speakers Same mono playback bus
- CAM → CAP2 separate 3G-SDI lines
- CAP → PC2 USB 3 video paths; test host topology
- PC → DIS2 HDMI outputs; layout depends on app
- PC ↔ REMIP call and application content sharing
- MIC → DSPDante: 2 processed automixes to RX1 / RX2
- DSP → SPKTX1 multicast: 1 flow to 4 speakers
- DSP → MICTX2 multicast: 1 flow to both AEC references
- DSP → PCUSB send: mixed local speech only
- PC → DSPUSB playback: far end + content
Playback never enters the USB microphone send. No automatic tracking, local voice lift or certified room platform claimed. Panel presets and application camera selection are separate actions. Reference design: project selection and tests required.
Control & power
All 5 connections · 6 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · PANEL1 IP room panel Sound, PTZ presets, display controls
To · DSP1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
Direction: source → destination · IP commands
From · DSP1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
To · PANEL1 IP room panel Sound, PTZ presets, display controls
Direction: source → destination · Confirmed device status / fault
From · DSP1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
To · CAM2 SDI PTZ cameras Separate 12 V supply per camera
Direction: source → destination · VISCA/IP presets; not app camera select
From · DSP1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
To · DIS2 displays 86-inch candidates; independent outputs
Direction: source → destination · Agreed IP commands / status
From · SW1 managed room switch 14 copper links used; require at least 16 7 PoE devices; PSE at least 240 W
To · NWPhysical port schedule 2 arrays + 4 speakers + panel: Ethernet and PoE Processor + PC + 2 cameras + 2 displays + uplink: Ethernet only AV VLAN: configured multicast and querier
Direction: source → destination · Physical connections; see port schedule
CAM · 2 SDI PTZ cameras Separate 12 V supply per camera
Connections: L12. Repeated device IDs refer to the same equipment.
DIS · 2 displays 86-inch candidates; independent outputs
Connections: L13. Repeated device IDs refer to the same equipment.
DSP · 1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
Connections: L10, L11, L12, L13. Repeated device IDs refer to the same equipment.
PANEL · 1 IP room panel Sound, PTZ presets, display controls
Connections: L10, L11. Repeated device IDs refer to the same equipment.
SW · 1 managed room switch 14 copper links used; require at least 16 7 PoE devices; PSE at least 240 W
Connections: L14. Repeated device IDs refer to the same equipment.
NW · Physical port schedule 2 arrays + 4 speakers + panel: Ethernet and PoE Processor + PC + 2 cameras + 2 displays + uplink: Ethernet only AV VLAN: configured multicast and querier
Connections: L14. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 5 connections
- Two captures feed the PC for manual camera selection. Two processed microphone mixes feed the call, while playback returns to four speakers and both echo references.
- MR-03 reference diagram showing two cameras and displays, two microphone arrays, audio return, room controls and the managed network.
- CAM
- 2 SDI PTZ cameras Separate 12 V supply per camera
- DIS
- 2 displays 86-inch candidates; independent outputs
- DSP
- 1 USB audio / control processor 2 active Dante RX + 2 TX; no second AEC
- PANEL
- 1 IP room panel Sound, PTZ presets, display controls
- SW
- 1 managed room switch 14 copper links used; require at least 16 7 PoE devices; PSE at least 240 W
- NW
- Physical port schedule 2 arrays + 4 speakers + panel: Ethernet and PoE Processor + PC + 2 cameras + 2 displays + uplink: Ethernet only AV VLAN: configured multicast and querier
- PANEL → DSPIP commands
- DSP → PANELConfirmed device status / fault
- DSP → CAMVISCA/IP presets; not app camera select
- DSP → DISAgreed IP commands / status
- SW → NWPhysical connections; see port schedule
Playback never enters the USB microphone send. No automatic tracking, local voice lift or certified room platform claimed. Panel presets and application camera selection are separate actions. Reference design: project selection and tests required.
Typical architecture · not a project drawing