HS-03 · Club stage & lounge
Stage PA, lounge audio, LED video and DMX lighting have distinct signal paths and operating responsibilities.
Video & data
All 2 connections · 3 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · PLAYER1 video player silent visuals in base scope
To · LEDP1 LED processor
Direction: source → destination · HDMI
From · LEDP1 LED processor
To · LED1 LED surface cabinets + receiver cards count by geometry
Direction: source → destination · matched LED data links not a general LAN switch
PLAYER · 1 video player silent visuals in base scope
Connections: L10. Repeated device IDs refer to the same equipment.
LEDP · 1 LED processor
Connections: L10, L11. Repeated device IDs refer to the same equipment.
LED · 1 LED surface cabinets + receiver cards count by geometry
Connections: L11. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 2 connections
- Stage PA, lounge audio, LED video and DMX lighting have distinct signal paths and operating responsibilities.
- HS-03 reference diagram showing active stage speakers with individual power, independent lounge sound, LED data and isolated lighting branches.
- PLAYER
- 1 video player silent visuals in base scope
- LEDP
- 1 LED processor
- LED
- 1 LED surface cabinets + receiver cards count by geometry
- PLAYER → LEDPHDMI
- LEDP → LEDmatched LED data links not a general LAN switch
3 end terminators one per active branch
DMX is one-way here cue state is not fixture telemetry each fixture also requires AC power
Shared: rack, signal cables, power, mounting and licences 4 separate PA AC feeds + 12 lighting feeds + LED power by design No external power amplifier for active PA Stage monitors are an option; add aux feeds, AC and mute coverage
Reference quantities, not a coverage or capacity guarantee No automatic timecode show or fixture feedback in this baseline AV programme mute does not replace certified voice alarm
Audio & return paths
All 9 connections · 11 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · DJ1 guest DJ set
To · DI1 stereo line isolation
Direction: source → destination · stereo line
From · DI1 stereo line isolation
To · MIX1 stage mixer 6 of ≥8 inputs used
Direction: source → destination · CH1/2
From · MIC4 wired microphone channels
To · MIX1 stage mixer 6 of ≥8 inputs used
Direction: source → destination · CH3–6
From · MIX1 stage mixer 6 of ≥8 inputs used
To · PROC1 speaker processor 2 inputs / ≥4 outputs limits, filters, delays, mute
Direction: source → destination · balanced L/R
From · PROC1 speaker processor 2 inputs / ≥4 outputs limits, filters, delays, mute
To · TOP2 active tops each: signal + AC
Direction: source → destination · OUT1/2: line L/R
From · PROC1 speaker processor 2 inputs / ≥4 outputs limits, filters, delays, mute
To · SUB2 active subwoofers each: signal + AC
Direction: source → destination · OUT3/4: line
From · BGM1 music player
To · DSP1 zone DSP 2 inputs / 1 output used
Direction: source → destination · analogue L/R
From · DSP1 zone DSP 2 inputs / 1 output used
To · AMP1 four-channel 100 V amplifier CH1 used; CH2–4 spare
Direction: source → destination · mono line
From · AMP1 four-channel 100 V amplifier CH1 used; CH2–4 spare
To · SPK4 ceiling speakers 6 W tap / 24 W line
Direction: source → destination · 1 independent 100 V line
DJ · 1 guest DJ set
Connections: L01. Repeated device IDs refer to the same equipment.
DI · 1 stereo line isolation
Connections: L01, L02. Repeated device IDs refer to the same equipment.
MIX · 1 stage mixer 6 of ≥8 inputs used
Connections: L02, L03, L04. Repeated device IDs refer to the same equipment.
MIC · 4 wired microphone channels
Connections: L03. Repeated device IDs refer to the same equipment.
PROC · 1 speaker processor 2 inputs / ≥4 outputs limits, filters, delays, mute
Connections: L04, L05, L06. Repeated device IDs refer to the same equipment.
TOP · 2 active tops each: signal + AC
Connections: L05. Repeated device IDs refer to the same equipment.
SUB · 2 active subwoofers each: signal + AC
Connections: L06. Repeated device IDs refer to the same equipment.
BGM · 1 music player
Connections: L07. Repeated device IDs refer to the same equipment.
DSP · 1 zone DSP 2 inputs / 1 output used
Connections: L07, L08. Repeated device IDs refer to the same equipment.
AMP · 1 four-channel 100 V amplifier CH1 used; CH2–4 spare
Connections: L08, L09. Repeated device IDs refer to the same equipment.
SPK · 4 ceiling speakers 6 W tap / 24 W line
Connections: L09. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 9 connections
- Stage PA, lounge audio, LED video and DMX lighting have distinct signal paths and operating responsibilities.
- HS-03 reference diagram showing active stage speakers with individual power, independent lounge sound, LED data and isolated lighting branches.
- DJ
- 1 guest DJ set
- DI
- 1 stereo line isolation
- MIX
- 1 stage mixer 6 of ≥8 inputs used
- MIC
- 4 wired microphone channels
- PROC
- 1 speaker processor 2 inputs / ≥4 outputs limits, filters, delays, mute
- TOP
- 2 active tops each: signal + AC
- SUB
- 2 active subwoofers each: signal + AC
- BGM
- 1 music player
- DSP
- 1 zone DSP 2 inputs / 1 output used
- AMP
- 1 four-channel 100 V amplifier CH1 used; CH2–4 spare
- SPK
- 4 ceiling speakers 6 W tap / 24 W line
- DJ → DIstereo line
- DI → MIXCH1/2
- MIC → MIXCH3–6
- MIX → PROCbalanced L/R
- PROC → TOPOUT1/2: line L/R
- PROC → SUBOUT3/4: line
- BGM → DSPanalogue L/R
- DSP → AMPmono line
- AMP → SPK1 independent 100 V line
3 end terminators one per active branch
DMX is one-way here cue state is not fixture telemetry each fixture also requires AC power
Shared: rack, signal cables, power, mounting and licences 4 separate PA AC feeds + 12 lighting feeds + LED power by design No external power amplifier for active PA Stage monitors are an option; add aux feeds, AC and mute coverage
Reference quantities, not a coverage or capacity guarantee No automatic timecode show or fixture feedback in this baseline AV programme mute does not replace certified voice alarm
Control & status
All 12 connections · 12 devices and services
Choose a connection to read its endpoints, direction and interface. Repeated device IDs refer to the same equipment across views.
From · LIGHT1 lighting console ≥1 DMX universe
To · SPLIT1 isolated splitter ≥4 outputs; 3 used
Direction: source → destination · DMX
From · SPLIT1 isolated splitter ≥4 outputs; 3 used
To · WASH8 wash fixtures ≤8 slots each
Direction: source → destination · branches 1/2 addresses 1–64
From · SPLIT1 isolated splitter ≥4 outputs; 3 used
To · MOVE4 moving fixtures ≤16 slots each
Direction: source → destination · branch 3 addresses 65–128
From · PAN2 staff panels lounge and duty manager
To · CTL1 system controller permissions + agreed presets
Bidirectional · IP commands / status
From · NET1 managed 16-port switch 12 ports assigned / reserved PoE budget ≥120 W
To · PAN2 staff panels lounge and duty manager
Direction: source → destination · LAN / panel PoE
From · FIRE1 building signal interface external contractor
To · ISO1 isolation interface set two programme mute paths
Direction: source → destination · agreed contact
From · CTL1 system controller permissions + agreed presets
To · DSP1 zone DSP 2 inputs / 1 output used
Bidirectional · IP source / gain / status driver to verify
From · CTL1 system controller permissions + agreed presets
To · PROC1 speaker processor 2 inputs / ≥4 outputs limits, filters, delays, mute
Bidirectional · IP agreed preset / status interface to verify
From · CTL1 system controller permissions + agreed presets
To · LEDP1 LED processor
Bidirectional · IP agreed commands / status
From · CTL1 system controller permissions + agreed presets
To · LIGHT1 lighting console ≥1 DMX universe
Bidirectional · IP cue commands / console state if supported by selected console
From · ISO1 isolation interface set two programme mute paths
To · PROC1 speaker processor 2 inputs / ≥4 outputs limits, filters, delays, mute
Direction: source → destination · contact: all stage outputs mute
From · ISO1 isolation interface set two programme mute paths
To · DSP1 zone DSP 2 inputs / 1 output used
Direction: source → destination · contact: lounge mute
PROC · 1 speaker processor 2 inputs / ≥4 outputs limits, filters, delays, mute
Connections: L19, L22. Repeated device IDs refer to the same equipment.
DSP · 1 zone DSP 2 inputs / 1 output used
Connections: L18, L23. Repeated device IDs refer to the same equipment.
LEDP · 1 LED processor
Connections: L20. Repeated device IDs refer to the same equipment.
LIGHT · 1 lighting console ≥1 DMX universe
Connections: L12, L21. Repeated device IDs refer to the same equipment.
SPLIT · 1 isolated splitter ≥4 outputs; 3 used
Connections: L12, L13, L14. Repeated device IDs refer to the same equipment.
WASH · 8 wash fixtures ≤8 slots each
Connections: L13. Repeated device IDs refer to the same equipment.
MOVE · 4 moving fixtures ≤16 slots each
Connections: L14. Repeated device IDs refer to the same equipment.
PAN · 2 staff panels lounge and duty manager
Connections: L15, L16. Repeated device IDs refer to the same equipment.
CTL · 1 system controller permissions + agreed presets
Connections: L15, L18, L19, L20, L21. Repeated device IDs refer to the same equipment.
NET · 1 managed 16-port switch 12 ports assigned / reserved PoE budget ≥120 W
Connections: L16. Repeated device IDs refer to the same equipment.
FIRE · 1 building signal interface external contractor
Connections: L17. Repeated device IDs refer to the same equipment.
ISO · 1 isolation interface set two programme mute paths
Connections: L17, L22, L23. Repeated device IDs refer to the same equipment.
Devices, connections & design conditions 12 connections
- Stage PA, lounge audio, LED video and DMX lighting have distinct signal paths and operating responsibilities.
- HS-03 reference diagram showing active stage speakers with individual power, independent lounge sound, LED data and isolated lighting branches.
- PROC
- 1 speaker processor 2 inputs / ≥4 outputs limits, filters, delays, mute
- DSP
- 1 zone DSP 2 inputs / 1 output used
- LEDP
- 1 LED processor
- LIGHT
- 1 lighting console ≥1 DMX universe
- SPLIT
- 1 isolated splitter ≥4 outputs; 3 used
- WASH
- 8 wash fixtures ≤8 slots each
- MOVE
- 4 moving fixtures ≤16 slots each
- PAN
- 2 staff panels lounge and duty manager
- CTL
- 1 system controller permissions + agreed presets
- NET
- 1 managed 16-port switch 12 ports assigned / reserved PoE budget ≥120 W
- FIRE
- 1 building signal interface external contractor
- ISO
- 1 isolation interface set two programme mute paths
- LIGHT → SPLITDMX
- SPLIT → WASHbranches 1/2 addresses 1–64
- SPLIT → MOVEbranch 3 addresses 65–128
- PAN ↔ CTLIP commands / status
- NET → PANLAN / panel PoE
- FIRE → ISOagreed contact
- CTL ↔ DSPIP source / gain / status driver to verify
- CTL ↔ PROCIP agreed preset / status interface to verify
- CTL ↔ LEDPIP agreed commands / status
- CTL ↔ LIGHTIP cue commands / console state if supported by selected console
- ISO → PROCcontact: all stage outputs mute
- ISO → DSPcontact: lounge mute
3 end terminators one per active branch
DMX is one-way here cue state is not fixture telemetry each fixture also requires AC power
Shared: rack, signal cables, power, mounting and licences 4 separate PA AC feeds + 12 lighting feeds + LED power by design No external power amplifier for active PA Stage monitors are an option; add aux feeds, AC and mute coverage
Reference quantities, not a coverage or capacity guarantee No automatic timecode show or fixture feedback in this baseline AV programme mute does not replace certified voice alarm
Typical architecture · not a project drawing