Compact LED wall VW-01

Reference design; receiver compatibility and power data pending.

Discuss this option →

How it works · VW-01

One source. One continuous picture.

2.56 × 1.44 m 1376 × 774 px

Wall layout & signal flow

12 cabinets · front elevationData enters at the top ↓

← 2.56 m →Height 1.44 m

One full-surface source. No automatic backup. LED data bypasses the control LAN.

Control & power

Setup & supported status

Verify feedback with the supplied cabinet assembly.

Separate electrical supply

Power circuits are independent of the 4 data columns. Cabinet power, circuit count, receiver compatibility and supported feedback still require confirmation.

Port, cabinet & service schedule Engineering details

Reference design · not a tested system. Cabinets are logical receiver groups. Physical receiving-card model, count, scan and configuration revision remain TBD; the supplier must confirm them.

All active output rectangles start at y = 0. The selected mode is 60 Hz, 8 bit, 2D normal. Each port carries 266,256 pixels against a 650,000-pixel limit. P5 and P6 are unused, not backup outputs. There is no return cable or automatic backup in the baseline.

P1 · Column 1

Origin 0, 0 · 344 × 774 px
Load 266,256 / 650,000 px

  1. C01-01Origin 0, 0 · 344 × 258 px
    Next: C02-01
  2. C02-01Origin 0, 258 · 344 × 258 px
    Next: C03-01
  3. C03-01Origin 0, 516 · 344 × 258 px
    Next: END

P2 · Column 2

Origin 344, 0 · 344 × 774 px
Load 266,256 / 650,000 px

  1. C01-02Origin 344, 0 · 344 × 258 px
    Next: C02-02
  2. C02-02Origin 344, 258 · 344 × 258 px
    Next: C03-02
  3. C03-02Origin 344, 516 · 344 × 258 px
    Next: END

P3 · Column 3

Origin 688, 0 · 344 × 774 px
Load 266,256 / 650,000 px

  1. C01-03Origin 688, 0 · 344 × 258 px
    Next: C02-03
  2. C02-03Origin 688, 258 · 344 × 258 px
    Next: C03-03
  3. C03-03Origin 688, 516 · 344 × 258 px
    Next: END

P4 · Column 4

Origin 1032, 0 · 344 × 774 px
Load 266,256 / 650,000 px

  1. C01-04Origin 1032, 0 · 344 × 258 px
    Next: C02-04
  2. C02-04Origin 1032, 258 · 344 × 258 px
    Next: C03-04
  3. C03-04Origin 1032, 516 · 344 × 258 px
    Next: END

Devices & connections

source
Content PC × 1 HDMI 1920 × 1080p60 Prepared wall canvas
controller
Combined LED controller × 1 Scaler + sender; one selected source 4 loaded outputs; 60 Hz / 8 bit No automatic backup in baseline
wall
LED surface × 12 cabinets 4 × 3 · 2.56 × 1.44 m 1376 × 774 canvas 4 logical column chains 12 included receiver / PSU sets Physical card model / count TBD
service
Support laptop × 1 Setup and supported status Local authorised access
network
Control LAN switch × 1 INF: shared infrastructure LED DATA bypasses this switch
power
Power distribution × 1 set Protected supply: display + rack Cabinet power / circuits TBD
  1. L01 · Content PC × 1 → Combined LED controller × 1HDMI
  2. L02 · Combined LED controller × 1 → LED surface × 12 cabinetsLED DATA × 4
  3. L03 · LED surface × 12 cabinets → Combined LED controller × 1Supported receiver status; verify supplied assembly
  4. L04 · Support laptop × 1 ↔ Control LAN switch × 1IP
  5. L05 · Control LAN switch × 1 ↔ Combined LED controller × 1Control / status
  6. L06 · Power distribution × 1 set → LED surface × 12 cabinetsDisplay mains
  7. L07 · Power distribution × 1 set → Combined LED controller × 1Rack mains

Service & structure

Front removal paths, tools and clearance must be drawn for the chosen mounting system. Structural loads include the cabinets, frame, cabling and service loads. Power circuits are independent of the data columns. Cabinet power and circuit count depend on the supplied specification.

Open printable cabinet map ↗